Description
To let ACK repair supported node faults, set both enable and auto_repair to true in the managed node pool’s management block.
Potential impact
Without auto repair or an alternative response, a failed node can remain unavailable and interrupt workloads.
Remediation
Check that ack-node-problem-detector is running and review node repair events. Allow enough spare capacity for workloads to run while a node restarts and check how many nodes can be unavailable at once.
Examples
Both examples request one node. The second also enables automatic upgrades and sets max_unavailable = 1, so the only node may be unavailable. Supply the omitted node authentication and disk settings.
Before
hcl
resource "alicloud_cs_kubernetes_node_pool" "default" {
name = var.name
cluster_id = alicloud_cs_managed_kubernetes.default.0.id
vswitch_ids = [alicloud_vswitch.default.id]
instance_types = [data.alicloud_instance_types.default.instance_types.0.id]
desired_size = 1
}
After
hcl
resource "alicloud_cs_kubernetes_node_pool" "default" {
name = var.name
cluster_id = alicloud_cs_managed_kubernetes.default.0.id
vswitch_ids = [alicloud_vswitch.default.id]
instance_types = [data.alicloud_instance_types.default.instance_types.0.id]
desired_size = 1
management {
enable = true
auto_repair = true
auto_upgrade = true
surge = 1
max_unavailable = 1
}
}